Home > Products Introduction > Temp.controller   
   
 Summary
Programmable
PID
General
Special Purpose
Indicator
Others
 

?
 
     * TD500
    - 2 LOOP max 100 pat., 100 seg./1 pat.
  - Color LCD screen (Touch panel type)
  - Digital Input 8 contacts, Digital Output 16 contacts
  - Various alarms (Output: 4 contacts, Operation: 20 kinds )

 
             
   
     
 

Input specification
Input (2 channels) Pt100 ( IEC 751 )
- 200 ~ 640 ﹉C , ▽ 0.1% of F.S
TC_K
- 200 ~ 1370 ﹉C , ▽ 0.1% of F.S
TC_J
- 200 ~ 1200 ﹉C , ▽ 0.1% of F.S
TC_E
- 200 ~ 1000 ﹉C , ▽ 0.1% of F.S
TC_T
- 200 ~ 400 ﹉C , ▽ 0.1% of F.S
TC_R
0 ~ 1700 ﹉C , ▽ 0.15% of F.S
TC_S
0 ~ 1700 ﹉C , ▽ 0.15% of F.S
m V
0 ~ 100 mV or - 10 ~ 20 mV (- 999.9 ~ 9999.9) ,▽ 0.1% of F.S
V d.c
0 ~ 10 V (Signal input range setup is available, - 999.9 ~ 9999.9) ,▽ 0.1% of F.S
4 - 20 mA
Use 250 目 external resistance, V d.c use after setup of V d.c 1 - 5 V
Input resolution
24 bit
a.ccura.cy of indication
0.1 ﹉C
Sampling cycle
Ea.ch channel 500 msec
Input resistance
More than 1 M目
Maximum allowable resistance of line
Less than 50 目 / Line (Resistance of lines is a same condition))
R J C
▽ 1.5 ﹉C

Output specification
Control Output S C R
4 - 2 mA d.c(Resistive load : less than 600 目 Output resolution : 16 bit
a.ccura.cy of output : ▽0.1 % of F.S Output ripple : 0.2 % of F.S
S S R
24 V d.c pulse(resistive load : More than 600目) Min. Pulse range : 10 ms
Cycle time : Available to select 1 - 1000s
Relay Output
External relay by using internal relay or TR output(Max. 24V, 100mA)
Kind of internal relay : N / O -> 250V a.c 5A / 30V d.c 5A
N / C -> 250V a.c 2A / 30V d.c 1A
Transmission Output ( 4 - 20 mA )
Available to select PV / SV / H.MV / C.MV of each channel. Output accuracy : ▽ 0.1% of F.S
In case of heating / cooling control, if control output of heating is SCR or SSR,
this channel can not use transmission output.
Transmission Output
Period of output renewal
Each channel 500 ms

Functions
Screen
5.7 Inch color LCD and interface with touch panel
Pattern
Max 100, available to operate each channel's pattern
Segment
Max 2,400(Max 100 per segment)
Waiting mode
Setup per pattern and setup of using or not using per segment
Repetition & Connection
Available to use pattern repetition and section repeat loof setup(Max 20) free connecting operation
among patterns is available .
P I D group
Each channel 4 zones, selectable between manual or automatic
Control method
Heating control or heating/cooling control in each channel. PID or ON/OFF control
Auto Tuning
Optimal PID GAIN is automatically calculated according to set value.
Proportional band
0.0 ~ 1000.0 ﹉C ( If "0" = On/Off control, Not "0" = PID control)
Integral time
0 ~ 6000 sec ( "0" = No integral calculation )
Differential time
0 ~ 6000 sec ( "0" = No differential calculation )
On / Off control
Available to select dead zone 0.1 ~ 1000.0 ﹉C
Event log
Max 40 event logs could be saved depend on various situations
LCD protection
Back light will be off according to designated time of not using touch panel
Password
Password is available to prevent other people from changing system setup
Protection of over
integral and differential
ARW ZONE setup ( 50 ~ 200% of proportional band )
Fuzzy function
Control overshoot
RAMP
Available to select SV changing ratio in case of fixing operation
Restrict MV
changing ratio
Function to control sudden change of MV
Alarm setup
4 points, High, Low, Deviation etc. 20 kinds
Inner signal
8 points, object, range and delayed time setup are available
Time signal
8 points when program mode operation
Graph function
PV, SV of each channel could be display by graph
Fixing operation hour
Available to set fixing opertaion hour up
Reservation operation
function
Available to use reservation operation time by using built in timer
User logo display
User logo could be shown for 3 sec after power on. Download throught communication port
Screen capture
Upload is available throught communication port
Language
Korean and English
Contact input
RUN / STOP, STEP, HOLD and error input(stop operation, delayed / setup is available)
Contact output
Output of various signals
Storage in power failure
Setup and operation information is saved in inner flash memory of NVRAM
Return from powe failure
STOP / COLD / HOT could be returned in case of power failure

Communication
Applied standard EIA-RS232C, EIA-RS422 / 485, USB
Type RS232 RS422 / 485
Max. connection number 1 : 1 1 : 256
Communication method Full duplex 4 wired half duple, 2 wired half duplex
Synchronous method asynchronous
Communication distance within approximately 10 m within approximately 1.2 km
Communication speed 2400 ~ 115200
Length of data 8 bits
Parity Bit NONE
Stop Bit 1 bit(s)
Communication protocol PCLINK + CHECK SUM
Delayed responce time 1 + (0 ~ 250) ms

Ratings
Rated voltage
100 ~ 240 V a.c , vailable voltage ratio : ▽ 10 %
Frequecy
50 / 60 Hz
Power consumption
Main body : MAX 16 W, I / O board : Max. 20 W
Insulation resistance
Between 1st & 2nd terminal
1st / 2nd and earth terminal
More than 20 M目 / 500 V d.c
Withstanding voltage
Between 1st & 2nd terminal
1st / 2nd and earth terminal
2500 V a.c, 50 / 60 Hz, 1 min
Power output
24 V d.c , 500 mA Max

Model Code Description
T D 5 0 0
2 Loop programmable temperature controller
Body(Separate Type) N
None
1

Separate body(RS422 / 485 + USB)

2
Separate body(RS232C + USB)
Body(Unit) 3
Unit body(RS422 / 485 + USB), I / O terminal built-in
4
Unit body(RS232C + USB), I / O terminal built-in
I / O Board N
No I / O board
1
Separate type I / O board

20070404_01