| MODEL |
NX9 |
NX7 |
NX2 |
NX3 |
NX4 |
NX1 |
|
Appearance (mm) |
|
|
|
|
|
 |
 |
48(W) x 24(H)
x 100(D) |
|
|
Function |
| ¤ýFuzzy |
¤ýAuto tuning |
| ¤ýExternal contact input |
¤ýHeater Break Alarm(HBA1) |
| ¤ýInput filter : OFF, 1~120sec |
¤ýZone PID |
| ¤ý2 Alarm outputs |
¤ýOutput Limitation |
| ¤ýInterface(RS/485/422) |
¤ýRetransmission output
(PV, SV, MV) |
| ¤ýGroup PID |
¤ýUniversal-input/output |
| ¤ýHeating/Cooling control |
¤ýIP 65 front facia |
| ¤ýHeating/Cooling
hysteresis |
|
|
| Input |
| Thermocouple
: K, J, E, T, R, S, B, L, N, U, WRe 5-26, PL-II |
R.T.D : Pt 100§Ù, KPt 100§Ù |
| Direct voltage : 1~5V, 1~10V, -0~20mV, 0~100mV --------------(Free scale type) |
|
|
Sampling cycle |
250ms |
|
Input display resolution |
Below decimal point of Input signal and Measuring range |
| Input
impedance |
T/C
and mV input : Min, 1M§Ù DC V : 1M§Ù |
|
Source tolerable resistance |
Thermocouple
: Max. 250§Ù, Voltage : Max. 2 k§Ù |
|
Lead wire tolerable resistance |
R.T.D
: Max. 150§Ù / wire
(notice : Identical conductor resistance between 3wires) |
|
Input tolerable voltage |
¡¾10V
(T/C, R.T.D, Voltage : mV DC), ¡¾20V(Voltage : V DC) |
|
Noise removal rate |
NMRR(Nomal
mode) : 40dB min.
/ CMRR(Common mode) : 120dB min.(50/60Hz ¡¾1%) |
| Standard |
T/C,
R.T.D : KS, IEC, DIN |
|
Standard junction temp. |
¡¾1.5¡ÆC(15~35 ¡ÆC),
¡¾2.0¡ÆC(0~50 ¡ÆC) |
|
Burn-oup |
T/C
: OFF, Up/Down selectable /
R.T.D : OFF, UP selectable (Detection current : 50mA) |
| Accuracy |
¡¾0.5%
(Full scale) |
| Power
supply for sensor |
DC
24V(Internal resistance : 1.2 k§Ù) Max 50mA /
DC 15V(Internal resistance : 790 ¡ÆC) |
| Model |
Suffix code |
Description |
| NX1 - |
 |
 |
Multi input, output temp. controller 48(W) x 24(H) x 100(D) mm |
| Control type |
0 |
|
Universal type |
| 1 |
|
Heating / Cooling |
| Universal type selection |
|
Optional |
Heating Output |
Cooling Output |
| 0 |
None |
Relay |
- |
| 1 |
None |
S.S.R / S.C.R |
- |
| 2 |
RS485 |
Relay |
- |
| 3 |
RS485 |
S.S.R / S.C.R |
- |
| 4 |
ALM |
S.S.R / S.C.R |
- |
| 5 |
ALM / RS485 |
S.S.R / S.C.R |
- |
| 6 |
RET |
Relay |
- |
| 7 |
RS485 / RET |
Relay |
- |
| Heating / Cooling selection |
0 |
None |
Relay |
S.S.R / S.C.R |
| 1 |
None |
S.S.R / S.C.R |
Relay |
| 2 |
RS485 |
Relay |
S.S.R / S.C.R |
|
| Model |
Code |
Description |
| NX |
- |
 |
 |
Multi input, output
temp.
controller |
| 2 |
|
|
48(W) x 96(H) x 100(D) mm |
| 3 |
|
|
96(W) x 48(H) x 100(D) mm |
| 7 |
|
|
72(W) x 72(H) x 100(D) mm |
| 9 |
|
|
96(W) x 96(H) x 100(D) mm |
| Control Type |
0 |
|
Universal type(Heat Control) |
| 1 |
|
Heating / Cooling |
| NX7, NX9
Selection |
0 |
None |
| 1 |
RS485, HBA |
| NX2, NX3
Selection |
0 |
SV2, SV3 |
| 1 |
HBA |
| 2 |
RS485 |
|
| Model |
Code |
Description |
| NX4 |
 |
 |
Multi input, output temp. controller
48(W) x 48(H) x 100(D) mm |
| Control type |
0 |
|
Universal type(Heat Control) |
| 1 |
|
Heating / Cooling |
| NX4
Selection |
0 |
None |
| 1 |
HBA, AL2 |
| 2 |
SV2, SV3 |
| 3 |
RET, RS485 |
| 4 |
RS485, SSR / SCR |
| 5 |
AL1, AL2 |
| 6 |
AL1, AL2, SV2 |
| 7 |
RS485, HBA |
| (note) |
Selection1 : OUT1(terminal 1 - 2 - 3) apply to AL1 |
|
in case of selection of S.S.R / S.C.R control output |
|
Selection3 : OUT2(terminal 11 - 12) apply to RET |
|
Selection4 : OUT2(terminal 11 - 12) apply to S.S.R / S.C.R |
|
Selection5 : OUT1(terminal 6 - 7) apply to SV2 |
|
Selection6 : OUT1(terminal 6 - 7) apply to SV2 |
|
in case of Relay control output |
|
|