| Model |
MC9 |
| Size(mm) |
96(W) x 96(H) x 100(D) |
| Function |
| ¡¤Multi channels PID control device |
¡¤Various alarm function(15 types) |
| ¡¤Multi memory function(max 8 x 8 units) |
¡¤8/4 channels control device |
| ¡¤DI contact input function |
¡¤Heating/cooling function |
| |
(but, only 4 channels are possible) |
|
| Power
Voltage |
110 - 220 V a.c(50 - 60 Hz) |
| Power
Consumption |
100 V a.c(below 14 VA) / 240 V a.c(below 20 VA) |
| Input |
4 or 8 channel(Sampling Time : 1s) Type(TC, RTD, d.c V) / Input impedance(approx. 1 M¥Ø) |
| Output |
Type(Relay Output, Voltage Pulse Output, TRIAC,4~20 mA Output, 0~20 mA Output) |
| Alarm |
1 a Contact Type / 250 a.c, 1 A(for resistive load) / Life time : above 300,000 times ON / OFF |
| Communication |
| EIA RS485 / RS232C, max connectable units : 31 units (for RS485, Address can be set from 1 to 99) |
| Communication method : 4-wire half duplex / 2-wire half duplex, Communication Protocol : PC-LINK |
|
| Contact input |
From below 2k¥Ø, ON, From above 15 k¥Ø, OFF |
| HBA |
| Input : Current Transformer(CT) / 0 ~ 100 A |
| Accuracy : a larger value among(+/-) 5% of Span or(+/-) 2 A |
|
| Operating
Environment |
| Temperature : 0~50 ¡ÆC(32 ¡ÆF ~ 122 ¡ÆF), |
| Humidity : 45 ~ 85 % RH(but, without condensation |
| Magnetic field : below 400 AT/m Without poisonous gas and without full of dust |
|
| Model |
Suffix code |
Description |
| MC9-4 |
 |
 |
 |
 |
 |
 |
 |
| 4 Channels Temp. Controller |
|
| Control
Direction |
D |
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
| W |
|
|
|
|
|
|
|
| Input |
 |
 |
|
|
|
|
|
| Output 1 ~ 4
(Heating Output) |
M |
|
|
|
|
| S |
|
|
|
|
| T |
|
|
|
|
| 4 |
|
|
|
|
| 5 |
|
|
|
|
Output 5 ~ 8
(Cooling Output)
- In case of D or R control direction,
it is fixed to 'N'
- In case of W control direction,
choose among M, S, T, 4, 5
|
N |
|
|
|
| M |
|
|
|
| S |
|
|
|
| T |
|
|
|
| 4 |
|
|
|
| 5 |
|
|
|
Option
(Contact Input & HBA))
* Loading Alarm Output AL1 basically |
N |
|
|
| 1 |
|
|
| 2 |
|
| AL2, 3 + RS232 + Contact Input |
|
| 3 |
|
| AL2, 3 + RS422 / 485 + Contact Input |
|
| 4 |
|
|
| Power Voltage |
1 |
| 24 V a.c / d.c (50-60 Hz) - Not ready |
|
| 2 |
|
| 3 |
|
| Model |
Suffix code |
Description |
| MC9-8 |
 |
 |
 |
 |
 |
 |
 |
| 8 Channels Temp. Controller |
|
| Control
Direction |
D |
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
| Input |
 |
 |
|
|
|
|
|
| Output 1 ~ 4 |
M |
|
|
|
|
| S |
|
|
|
|
| T |
|
|
|
|
| 4 |
|
|
|
|
| 5 |
|
|
|
|
| Output 5 ~ 8 |
N |
|
|
| None (Input 5 - 8 : Indicator)) |
|
| M |
|
|
|
| S |
|
|
|
| T |
|
|
|
| 4 |
|
|
|
| 5 |
|
|
|
Option
(Contact Input & HBA)
* Loading Alarm Output AL1, AL2 & AL3 basically |
N |
|
|
| 2 |
|
|
| 3 |
|
| RS422 / 485 + Contact Input |
|
| 4 |
|
|
| Power Voltage |
1 |
| 24 V a.c / d.c (50-60 Hz) - Not ready |
|
| 2 |
|
| 3 |
|
| Input type |
Input range( ¡ÆC ) |
Code |
| K |
| -200 ~ 1370 |
| -199.9 ~ 999.9 |
|
|
| J |
| -200 ~ 1200 |
| -199.9 ~ 999.9 |
|
|
| R |
|
|
| S |
|
|
| B |
|
|
| E |
| -200 ~ 1000 |
| -199.9 ~ 999.9 |
|
|
| N |
| -200 ~ 1000 |
| -199.9 ~ 999.9 |
|
|
| T |
-199.9 ~ 400.0 |
T0 |
| W |
0 ~ 2300 |
W0 |
| PL2 |
0 ~ 1390 |
A0 |
| U |
-199.9 ~ 600.0 |
U0 |
| L |
-199.9 ~ 900.0 |
L0 |
| Pt100 |
-199.9 ~ 600.0 |
D0 |
| JPt100 |
-199.9 ~ 500.0 |
P0 |
|
| -199.9 ~ 999.9 |
| -199.9 ~ 999.9 |
| -199.9 ~ 999.9 |
|
|
|