| Model |
HY-72 I |
| Rated Voltage |
110 / 220 V a.c, 60 Hz (universal) But, HY-48D,
48I are Selected by the Internal Dip S/W (Default : 220 V a.c) |
Permissible Voltage
Fluctuation Range |
Rated Voltage ▽10% |
| Consumption Power |
Approx. Max. 3 VA |
| Input |
Thermocouple, Resistive, DC
Current, DC Voltage |
| Adjusting Sensitivity |
▽ 0.2 % F.S (fixed) |
| Control Method |
| HY-8000, 72D, 48D |
HY-8200S |
| - Time Proportion ON/OFF |
- Time Proportion + ON / OFF |
| |
- ON / OFF + ON / OFF |
|
| Setting Method |
Set by BDC Switch |
| Display Method |
LED 7 Segment all Display |
| Control Output |
Relay Output : Capacity 250 V a.c 3 A
(Resistive Load) Contact : 1c |
SSR Output : 12 V a.c
(Constant Voltage Pulse)
(Resistive Load: above 800目 ) |
Current Output : 4 - 20 mA d.c
(Resistive Load : Below 600目 ) |
|
|
| Setting Accuracy |
Below ▽ 0.5 % F.S |
| Display Accuracy |
Below ▽1.0 % of Max. Range |
| Proportional Band |
| HY-8000S, HY-8200S, HY-72D : |
HY-48D |
| Approx.1 ~ 10 % of Max. Range (Variable) |
Approx. 3% of Max. Range (fixed) |
|
| Proportional Cycle |
Relay Output : 25 ~ 30 sec,
SSR Output : 2 ~ 4 sec |
| External Input Resistance |
Thermocouple : Below 100 , Resistive : Below 10
目(But, the 3 Wires Should have the Same Resistance) |
| Resolution |
1 ﹉C (pt100 目 - 49.9 ~ 199.9 : 0.1 ﹉C) |
| Dielectric Strength |
2000 V a.c 50 ~ 60 Hz for 1 Minute
(Between Terminals After Charging 2 Polar) |
Operating Ambient
Temperature / Humidity |
0 ~ 50 ﹉C, 35 ~ 85 % RH(Without Condensation) |
| Model |
Suffix Code |
Description |
| HY - |
 |
 |
 |
 |
 |
 |
HY-8000S, HY-8200S, HY-800S, HY72D, HY72I, HY-48D, HY-48I |
| Adjusting
Action |
F |
|
|
|
|
|
2 Position Control (ON / OFF) |
| P |
|
|
|
|
|
Proportional Action |
| Input |
K |
|
|
|
|
K (CA) |
| J |
|
|
|
|
J (IC) |
| R |
|
|
|
|
R (PR 13%) |
| D |
|
|
|
|
Pt 100 目 (KS standards) |
| P |
|
|
|
|
Pt 100 目 (DIN standards) |
| V |
|
|
|
|
1 - 5 V d.c |
| C |
|
|
|
|
4 - 20 mA d.c |
| Control Output |
M |
|
|
|
Relay Contact |
| C |
|
|
|
Current (4 - 20 mA d.c) |
| S |
|
|
|
SSR driving (Voltage Pulse 12 V d.c) |
| Alarm Output or Operation |
N |
|
|
None |
| O |
|
|
*High Limit Operation Output |
| Control Action |
R |
|
Reverse Action Control (for Heating Control) |
| D |
|
Direct Action Control (for Cooling Control) |
| Range Code |
|
Standard Range Code Number Selection |
| *Only For HY-8200S, it is standard. |
| *Mark the range code for temperature display (HY-800S, HY-72I, HY-48I) when
composing the model name and suffix code |
| *Alarm Output can not be specified other than model name HY-8200S |
Model /
Code No. |
HY-8000S / 8200S |
HY-800S |
HY-72D / 72I |
HY-48D / 48I |
| Input |
Temp. Range |
Input |
Temp. Range |
Input |
Temp. Range |
Input |
Temp. Range |
| 1 |
|
|
Pt |
-49 ~ 199 |
|
|
Pt |
-49 ~ 49 |
| 2 |
pt |
-99 ~ 99 |
Pt, K |
0 ~ 399 |
*Pt |
-99 ~ 99 |
*Pt |
-99 ~ 99 |
| 3 |
pt |
-99 ~ 99 |
K |
0 ~ 1199 |
Pt |
-99 ~ 199 |
Pt |
0 ~ 199 |
| 4 |
pt |
0 ~ 99 |
R |
600 ~ 1699 |
Pt |
0 ~ 99 |
Pt, K |
0 ~ 299 |
| 5 |
|
|
|
|
|
|
*Pt, K |
0 ~ 399 |
| 6 |
pt, K |
0 ~ 199 |
|
|
Pt, K |
0 ~ 199 |
|
|
| 7 |
pt, K |
0 ~ 299 |
|
|
Pt, K |
0 ~ 299 |
|
|
| 8 |
pt, K |
0 ~ 399 |
|
|
*Pt, K |
0 ~ 399 |
|
|
| 9 |
|
|
|
|
K |
0 ~ 599 |
|
|
| 10 |
K |
0 ~ 599 |
|
|
K |
0 ~ 799 |
|
|
| 11 |
K |
0 ~ 799 |
|
|
|
|
|
|
| 12 |
|
|
|
|
*K |
0 ~ 1199 |
|
|
| 13 |
K |
0 ~ 1199 |
|
|
*R |
599 ~ 1699 |
|
|
| 14 |
K |
600 ~ 1699 |
|
|
|
|
|
|
| * Display code is only available for model 72I, 48I |
|
|
No. |
Subject |
Name |
Date |
|
Not data |
|
|
|